CHAPTER 7 DATA 71
Note
When NOT using If volume = 0, speed = 0 feature, then if the volume in the interval
is zero, and the occupancy is less than 20%, the speed in the interval will be the speed
of the previous interval. If the volume in the interval is zero, and the occupancy is
more than 20%, the speed in the interval will be zero.
Storage
e Storage window allows you to turn on/o data storage; see a storage timeline, the stor-
age level and the amount of storage space remaining; and clear all storage on the sensor (see
Figure 7.5).
Figure 7.5 – Storage
Use the On/O switch to turn the sensor’s data storage feature on or o. If you check the
Stop when FULL checkbox, the sensor will stop storing data once the storage capacity is
reached, and consequently all new data will not be saved to memory.
e status section shows the date and time that the rst and last interval data packet was
stored and how much storage is remaining by both a status bar and a percentage. e Total
and Remaining elds show how long the sensor has been storing data and how long the sen-
sor will continue to store data before reaching maximum capacity. e capacity is tracked
in months, days, hours, minutes and seconds and is based upon the current sensor congu-
ration. e total number of intervals stored is dependent upon the number of congured
lanes, approaches and bin data types.
If data is stored with a dierent number of lanes, approaches or bin data types from the
current sensor conguration, the Tota l eld will be incorrect. In this case, the green status
bar is a better indicator of storage capacity. Additionally, using a virtual connection will also
cause the information in this screen to be incorrect.