CHAPTER 4 SENSOR TOOLBAR 43
e sensor interval is located in the Intrvl column on the sensor list. Sensor intervals are
limited by sensor rmware. Consult the sensor documentation to determine the acceptable
sensor intervals.
To specify the sensor interval:
1 Enter an interval value in the Set Sensor Interval To: eld. If the sensor is congured
so that it uses the sensor interval as the collection interval, the sensor and collection
intervals will automatically be set to the same value.
2 Click the Set Sensor Interval button. Once the interval is set, the results will be listed
for each sensor.
Note
Some sensor types do not support changing the sensor interval remotely. Consult
the individual driver documentation to see if changing the sensor interval via Collec-
tor is acceptable.
e collection interval represents how oen Collector attempts to connect to the sensor and
download the latest data packets. e collection interval is located in the Fq column on the
sensor list.
Note
Some sensors can store only the most recent data packets. In these cases, if the
collection interval diers from the sensor interval, data will be lost. Likewise, some
sensors have very limited memory for older data packets; therefore, large collec-
tion intervals might result in missed data (if the interim time exceeds the sensors
capacity to store older data packets).
You can only specify one interval at a time. If Collector uses the sensor interval as the col-
lection interval, any value entered into the Set Collection Interval To: eld will be disre-
garded. By default, Collector keeps the collection interval the same as the sensor interval
unless instructed otherwise. Consult individual sensor documentation to nd acceptable
collection intervals for Collector.
If a sensor allows collection intervals to be larger than sensor intervals, the sensor will col-
lect several data packets prior to Collector connecting and downloading the most recent
data (the data aer the most recent collection interval).
To specify the collection interval:
1 Enter an interval value in the Set Collection Interval To: eld. If the sensor is cong-
ured so that it uses the sensor interval as the collection interval, any value entered into
Seitenansicht 43