Wavetronix SMARTSENSOR 105 Betriebsanweisung Seite 76

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 107
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 75
CHAPTER 7 LANES & STOP BARS 75
Note
After you have mounted and aligned the sensor, you should always reboot the sen-
sor so that thresholds can adjust to the current view.
Editing Thresholds
Warning
You should only edit the Matrix thresholds under the direction of Wavetronix
Technical Services. If you believe that you need to adjust the thresholds, please call
Wavetronix at 801-734-7200 for assistance.
1 Click on the Edit resholds button. is will turn the sensors view green and allow
you to change the sensitivity of certain areas in the view.
2 Click anywhere within the sensors view and the Sensitivity window will appear (see
Figure 7.10).
Figure 7.10 – Sensitivity Window
e Sensitivity window contains the following options:
Adjust All – Allows you to edit all of the sensor thresholds.
Adjust Region – Allows you to adjust thresholds in a selected region of the sensor view.
Zoom In – Allows you to zoom in and change thresholds of selected areas in the sensor
view (see Figure 7.11).
Reset Region – Allows you to reset only a selected region of thresholds to default set-
tings.
Reset All – Allows you to reset all the sensor thresholds to default settings.
Seitenansicht 75