88 CHAPTER 8 ZONES & CHANNELS
Figure 8.12 – Output Settings (Normal, Counting, Pulse)
Detector Input – e Detector Input number provides a way for you to map inputs
to the intersection phase in the controller. By default, the Detector Input will be set
to “00;” if the input is left at “00,” then it is unassigned. is setting is for reference
purposes only and does not actually change the sensor.
Phase – Since the SmartSensor Matrix is capable of monitoring more than one phase,
this setting allows you to enter the phase number that most closely represents the
phase the sensor is monitoring. By default, the Phase will be set to “00;” if the phase is
left at “00,” then it is unassigned. is setting is for reference purposes only and does
not actually change the sensor.
Channel Type – is drop-down list allows you to select the type of channel (Normal,
Counting or Pulse). A normal channel is presence detection; a counting channel is
a special pulse based on counting algorithms; and a pulse channel is a generic pulse
based on zone presence.
Output Settings
e extend and delay settings can also be specied using the Output Settings button.
is button will open a window that will allow you to select individual channels to edit
and also to specify the minimum pulse width and pulsed channel width (Figure 8.13). e
minimum pulse width is the minimum duration a presence detection will be signaled via
the contact closure rack cards. e pulsed channel width is the duration the contact closure
message lasts for a pulse or counting channel. All output settings are specied in seconds.
Figure 8.13 – Output Settings Pop-up