CHAPTER 12 PROGRAMMING CONTACT CLOSURES 131
Note
A Click 100 16-output contact closure module can be used if the cabinet you are con-
necting to does not have an input file rack.
Select button
Settings switch
Display
Channel button
Channel LEDs
RS-485 ports
Figure 12.2 – Click 172/174 Cards
To program the Click 172/174 contact closure cards:
1 Plug the surge card into the input le rack. Make sure the Settings switch is in the 3
position when plugged in. Wait approximately 20 seconds.
2 Move the Settings switch to the 1 position and aer the auto-baud is complete, the cur-
rent mode will appear.
3 Toggle the Select button to select AC or Actuation mode.
4 Move the Settings switch to the 2 position and wait a few seconds.
5 Move the Settings switch to the 3 position.
6 Wait approximately 30 seconds and then conrm that the detections are registering on
the Channel LEDs.
In many cases, you can put multiple alerts on each channel to avoid the need for more than