CHAPTER 4 WEB-BASED MANAGEMENT 35
e Load the last stored conguration option can be used to reload the last conguration
saved on the device or the PC. All modications made to the conguration since it was last
saved will be lost (see Figure 4.14).
Figure 4.14 – Load the last stored configuration Setting
When a conguration is uploaded from the managed switch to a PC, the last saved version
is transmitted. If you want to transmit the active conguration, rst save it again (Save cur-
rent conguration function).
When a conguration is downloaded from a PC to a managed switch, the new congura-
tion is only activated once the switch has been reset.
Note
The use of a configuration file does not aect an existing (old) password.
Conguration using a conguration le is used when replacing devices. To duplicate de-
vices using a conguration le, observe the following:
Establish a point-to-point connection between a managed switch and the management
station.
Load the conguration le to the switch.
Reset the switch.
Adjust the IP parameters.
Save the conguration (Save current conguration function).
e duplicated switch can now be operated in the network using the adjusted IP param-
eters.
To trigger a reboot via the Web interface, enter a valid password. Save the conguration be-
forehand, so that conguration modications are retained or can be activated via a restart.
Ports Menu
e Ports menu is an overview of all available ports (see Figure 4.15). Clicking on the rel-
evant port number opens a port-specic page (Port Conguration).